|
|
|
Up To Whole House HeatingAmerican Heat Tankless Water Heater ADK Series ADK-14 58 Amps 208 Volts at 13.9kW allows 95°F Heat Rise in 1 Gallon per Minute or 63°F Heat Rise in 1.5 GPM. See Heat Rise Charts for higher flow rates. The ADK-14 is powerful enough to offer showering, sink faucet and washing machine flow rates as a stand alone unit or in combination with other ADK units in parallel for increased flow rate or tandem with lowered powered for same flow but greater heat rise. Note that more than one tankless unit may be needed dependant on the flow rate desired or the temperature of the incoming water in your location.
See our other ADK Series Tankless Water Heaters: ADK-16 ADK-14 ADK-12 ADK-9 ADK-7 ADK-4 Heat Rise and Specifications Ratings for Each Unit American Heat AH Series for Cold Climates or Extra GPMAmerican Heat Tankless Water Heater AHS Series with New Features for 2011 Heating ability ranges from 80° to 140° F. CSA approved, ETL#834 listed and UL#499 compliant for safe use in the USA AH18 Max of 75 Amps @ 240 Volts at 18.0kW 4.0 GPM at 105°F here in Miami with 80°F incoming water temperature. Shower heads usually do not exceed 2.5 GPM. Standard bath faucets usually run 2 to 4 Gallons per Minute, hot and cold. The AH18 is powerful enough to offer showering, sink faucet and washing machine flow rates with two or three items running at once here in Miami. Check your climate at the coldest incoming water temperatures to determine if this heater is right for you. Use the heat rise chart to determine your tankless water heater. Note that more than one tankless unit may be needed dependant on the flow rate desired or the temperature of the incoming water in your location. This is our 18 kilowatt unit. Interested in our 16, 18, 21, 24 or 27 Kilowatt units? Click Here *See our complete line of AHS Series Tankless Self-Regulating Water Heaters Heat Rise and Specifications Ratings for Each Unit American Heat AH Series for Extra Cold Climates or GPMAmerican Heat Tankless Water Heater AH Series (EXTRA COLD incoming Water) CSA, ETL and UL #499 Approval for safe use in your home AH27 112.5 Amps @ 240 Volts at 27kW 7.3 Gallons per Minute at 105°F Output here in Miami with our 80°F incoming water temperature. Shower heads usually do not exceed 2.5 GPM with both hot and cold water running. Standard bath faucets usually run 2 to 4 Gallons per Minute, hot and cold. So, this is a big electric tankless water heater. Make sure it is for you by comparing your incoming water temperature to our Heat Rise Charts with each unit. Before ordering, check your electric panel size in amps. You must have at least 200 amp service. The AHS21D, AHS24D, AHS27D are powerful enough to offer multiple showering, tub, sink faucet and washing machine flow rates with several items running at once here in Miami. Check your climate at the coldest incoming water temperatures to determine if this heater is right for you. Note that more than one tankless unit may be needed depending on the flow rate desired or the temperature of the incoming water in your location. This is our larget AH Unit which offer higher heating capactity for cold and extra cold climates or for homes needing large quantities of hot water. See our complete line of AHS Series Tankless Self-Regulating Water Heaters including the 16,18, 21, 24 & 27kW tankless water heaters Heat Rise and Specifications Ratings for Each Unit Remember our Manufacture's Limited Lifetime Warranty on the Water Carrying Parts. Three years on the electrical, excluding heating elements and one year on the heating elements. TextText
Electric Shower HeadHeat your water with the NEW American Heat Electric Shower Head. Simply screw on to your existing overhead plumbing as with any shower head. Then, plug this unit into a standard 110 Volt electrical socket. You must have 80+ F° incoming water with the 110 Volt unit. Or, the water will not be hot...takes the bite out of cold water though! (Please use a socket that supplies a good ground). Check with an electrician in your community. Comes as a standard 1.5 gpm with easy adaptation of a disk for 1.0 gpm flow. Expect around a 17 F° heat rise in 1.0 gpm flow rate. The American Heat Electric Shower Head is available for your safe use in the United States being ETL#834 listed and UL#499 Compliant. Consider Using a Siemens Subpanel and required breakrs on the AH Amerian Heat models. We DO NOT recommend simple cutoff boxes for these units. AHJ Tankless Water Heater....NO Heating Element![]() Our AHJ Tankless Water Heaters are rated at 18 and 21 kilowatts that you set the temperature with the push of a button. This is a separate line of new heaters at American Heat Direct that do not use the traditional elements. Your hot water is produced by a "Heat Generator" that is virtually maintenance free compared to any tankless water heater using heating elements. Great for use in areas of high mineral content in the water supply. No elements, no element buildup of energy robbing layered minerals. Self-Regulating 18 and 21 kilowatts of power More Information Order Now |
MyTankless@aol.com




